The biological filter is an artificial biological treatment technology developed based on the principle of soil self-purification and on the practice of sewage irrigation through artificial strengthening. It consists of a filler layer composed of filter materials such as crushed stone or plastic products. The sewage is evenly sprayed onto the filter layer from above and flows downward along the gaps in the filter under the action of gravity. The sewage is purified through filtration, adsorption and biological metabolism. Organic matter, ammonia nitrogen and other pollutants in the sewage are adsorbed by microorganisms on the surface of the filter material and decomposed into carbon dioxide, water and other harmless substances through the metabolism of microorganisms. In this process, microorganisms form a layer of biofilm on the surface of the filter material. The microorganisms in the biofilm mainly include bacteria, fungi, protozoa and metazoa, etc. They cooperate with each other to jointly remove pollutants in the sewage.
Common abnormal conditions in the operation of biological filters
First, it manifests itself in the abnormal shedding of biofilm. If the biofilm falls off too early or in large quantities, the treatment effect of the filter will be reduced, the water quality of the effluent will deteriorate, and there may be a loss of filter media. Because among the microorganisms parasitic on the biofilm, filamentous bacteria are more likely to dominate. If they flow into the biochemical system after peeling off, it is easy to induce the expansion of filamentous bacteria in the biochemical system.
In addition, if the biofilm is too thick, the deformation of the load-bearing filter media will be more serious. If a local collapse occurs, it will often aggravate the occurrence of overall collapse and local overcurrent load.
The sewage does not flow smoothly in the filter tank, water accumulation occurs, the water flow rate slows down significantly, the treatment capacity decreases, and odor may be generated.
The top of the biological tower is generally open. Due to direct sunlight, the biofilm will breed more algae at the top, resulting in the removal of organic matter in the top range of the biofilm. The discharged biological tower treated water appears turbid and opaque.
In addition to producing algae and affecting the treatment effect, another common fault of biofilm is that the color of biofilm is white instead of normal brown-yellow. The removal rate of organic matter in wastewater by this white biofilm is slightly lower than that of normal biofilm.
In addition, non-activated sludge protozoa such as bean-shaped worms and kidney-shaped worms can also be observed, mainly large non-activated sludge protozoa, rather than side springtail flagellates.
The appearance of non-activated sludge protozoa in biofilm and non-activated sludge protozoa in activated sludge method have different meanings.
In activated sludge method, most of them represent that the activated sludge system has been subjected to shock load, while the main reason for the appearance of non-activated sludge protozoa in biofilm of biological tower is that the surface of biofilm is in contact with air, which belongs to aerobic layer, while the middle of biofilm is anoxic layer, and when it comes to the attachment site of biofilm and filter material, anaerobic layer appears.
Therefore, most of the non-activated sludge protozoa in biofilm are species that can grow in anoxic environment.
In addition to the above abnormal conditions, common problems for aerated biological filters may include uneven aeration, uneven bubble size, insufficient or excessive aeration intensity, etc.
And the odor problem of the entire biological filter. The unpleasant odor around the filter is mainly the odor of hydrogen sulfide, ammonia and other foul-smelling gases, which has an adverse effect on the surrounding environment and the health of the staff.
Analysis of the causes of abnormal operation of biofilter
The first is the abnormal shedding of biofilm. The main reasons are excessive hydraulic load, changes in influent water quality, inappropriate temperature, aging of biofilm, impact of toxic substances, or improper backwashing frequency.
In the case of inappropriate environmental conditions, the water temperature is lower than 5℃ or higher than 40℃, the activity of microorganisms decreases; dissolved oxygen is insufficient or oversaturated for a long time. The impact of abnormal influent pH on biofilm is the greatest.
In terms of filter blockage, in addition to excessive suspended solids, thick biofilm, and insufficient backwashing, there may be improper selection of filter materials, such as small particle size that is easy to block, or unreasonable design of water distribution system leading to excessive local load.
In terms of aeration abnormality, in addition to equipment failure and flow control problems, it may also involve material problems of aeration heads, or insufficient air pretreatment leading to impurity blockage.
In terms of odor problems, in addition to untimely anaerobic decomposition and backwashing, there may also be climate factors, such as high temperature promoting anaerobic reaction, or poor ventilation leading to odor accumulation.
In addition, management and operational issues may need to be considered, such as untimely maintenance, insufficient monitoring frequency, inadequate emergency measures, etc. In addition, aging of filter materials or structural damage after long-term operation may also lead to abnormalities.
Countermeasures and adjustment strategies for abnormal operation of biofilter
First, the corresponding countermeasures for abnormal biofilm shedding should include adjusting the load, such as reducing the water intake or increasing the volume of the treatment tank; strengthening pretreatment to remove toxic substances; controlling water temperature, pH and dissolved oxygen; regular backwashing to prevent aging.
It is also necessary to adjust the water intake load, such as adding a regulating tank; adding microbial activators or nutrients; controlling the carbon-nitrogen ratio, adding carbon sources, etc.
Regarding filter blockage, pretreatment is required to reduce SS, such as adding a sedimentation tank or flotation; optimizing backwashing parameters, increasing intensity and time; or using alternating operation to allow the filter enough time to recover.
If the aeration of the aerated biofilter is abnormal, the response strategy includes checking the aeration system, cleaning or replacing the aeration head; adjusting the gas volume according to DO to ensure the appropriate gas-water ratio; and regular maintenance of the equipment to prevent blockage or leakage.
Solutions to odor problems include increasing aeration to prevent the formation of anaerobic zones and strengthening backwashing to remove sludge; using deodorizers or biofilters to treat exhaust gases; and optimizing the design, such as reducing filter depth or increasing water distribution uniformity.
About the poor growth of biofilm and its coping strategies
Under normal circumstances, the biofilm should be evenly covered on the surface of the filter material, with a yellow-brown or gray-brown color, with a certain degree of stickiness but not too loose.
Typical poor biofilm growth is mainly caused by the biofilm growing too thick or too thin. In addition, the more common is the uneven thickness of the biofilm growth.
When the organic matter in the influent is too low, the biofilm is thin; when the organic matter content in the influent is too high, the biofilm grows vigorously, and generally there is a too thick biofilm growing on the filter material.
In actual operation, it is found that the removal rate of organic matter by the biofilm is not necessarily higher than that of the thin biofilm. The reason is that the removal efficiency of organic matter in the wastewater by the biofilm is related to the effective contact area between the biofilm and the wastewater, but has nothing to do with the thickness of the membrane.
The lack of nutrients in the wastewater can be understood in the same way as the demand for nutrients in the operation of the activated sludge method. For this reason, nutrients need to be added before the water enters the biofilter. Since the amount of nutrients added needs to take into account the demand for nutrients by microorganisms in the biofilter and activated sludge process, the selection of the organic matter content value of the added nutrients should be more important. In actual practice, it is found that if a large amount of algae grows on the surface of the biofilter filter material. This will also reduce the treatment efficiency of the biofilter, usually reducing the removal efficiency by 10%. The reason is that the algae that grow do not have the ability to degrade organic matter in wastewater, and they only need nutrients and sunlight as the energy required for growth and reproduction. Regarding the abnormal change of the color of the biofilm to milky white, it is basically believed that it is related to the expansion of filamentous bacteria in the biofilm. When filamentous bacteria multiply in large numbers in the biofilm, the removal rate of the entire biofilter for organic matter in wastewater is not significantly reduced.
Although the ability of the biofilm to degrade organic matter in wastewater will not be significantly reduced after the milky white bacteria are produced, we will find that such filamentous bacteria are very likely to cause the subsequent outbreak of filamentous bacteria expansion in the activated sludge system. The main reason is that in daily operation, a certain amount of such white biofilm will peel off and flow into the subsequent aeration tank. Some of these filamentous bacteria that fall off and flow into the aeration tank will eventually be able to adapt to the new environment, thus forming a dominant population in the aeration tank and affecting the overall operating quality of the activated sludge system.
Regarding the problem of excessive moss growing in the biofilm, we can find that the moss on the illuminated side of the biofilm grows strongly, while the moss growth is not visible on the backlit side. Therefore, how to reduce the illuminated side of the biofilm is a key consideration in the design and transformation of the biofilter.
In addition, it is also important to reduce the addition of nutrients to the biofilter. Excessive addition of nutrients is also an important reason for the outbreak of moss growth in the biofilter.
For this reason, the nutrients of the entire biochemical system can be added in stages, that is, one dosing point is made on one side of the biofilter, and one dosing point is also made on the side of the aeration tank of the activated sludge method. In this way, the segmented addition of nutrients can avoid the problem caused by excessive addition of nutrients to the biofilter.
The growth of filamentous bacteria in biofilms will not have a big impact on the biofilm itself, but it may cause serious consequences for the subsequent activated sludge process and be detrimental to the entire biochemical system.
The response strategy focuses on the killing action after the system stops. The biofilter can be thoroughly cleaned with high sodium hypochlorite water to re-grow the biofilm.
The key to dealing with problems such as peeling and clogging caused by excessive growth of biofilms is to control the amount of return water.
The thickness of the biofilm can be suppressed through the brushing effect of high return water, which is also conducive to improving the removal rate of organic matter by the biofilm.