How To Deal With Sudden Changes in Water Quality in Sewage Treatment?

Leave a message

 

In the daily operation of sewage treatment, there are always some inexplicable situations in the data every once in a while. For example, COD has increased, total nitrogen has increased, and total phosphorus is almost uncontrollable. Of course, these are all traceable, and the situation is nothing more than wastewater equipment failure, seasonal temperature, and sudden changes in inflow water quality data fluctuations. For sewage equipment failures, inspections can be strengthened, and corresponding measures can also be taken for sudden changes in water quality.

sewage treatment plant 1

 

1. Establish a real-time monitoring system

Installing online monitoring equipment at the inlet can detect key water quality indicators such as chemical oxygen demand (COD), biochemical oxygen demand (BOD), ammonia nitrogen, heavy metal content, pH value, etc. in real time. Set a warning threshold, and once the monitoring data exceeds the set value, the operator should take corresponding measures and adjust the processing technology in a timely manner.

 

2. Emergency material reserve

Adequate reserve of emergency supplies is an important guarantee for sewage treatment plants to effectively respond to sudden changes in water quality. If conditions permit, various neutralizing agents should be stored, such as sulfuric acid and hydrochloric acid, to reduce excessively high pH values, and sodium hydroxide and lime water to increase excessively low pH values. These neutralizing agents need to be reserved according to the treatment capacity of the sewage plant and the possible pH fluctuations, and should usually ensure that they can meet at least one week's emergency treatment needs.

 

In terms of adsorbents, activated carbon is mainly used. Activated carbon has strong adsorption capacity and can effectively adsorb organic matter and some heavy metals. The reserve amount should be determined based on the treatment capacity of the sewage plant and the possible concentration of pollutants. It is recommended that the reserve amount should not be less than half a month's usage. At the same time, attention should be paid to the storage conditions of activated carbon, keeping it dry and ventilated to prevent a decrease in adsorption performance.

 

Coagulants and coagulants are also essential materials. Common coagulants include polyaluminum chloride (PAC) and polyferric sulfate (PFS), while coagulants include polyacrylamide (PAM). These agents can accelerate the coagulation and precipitation of suspended particles and colloids, improving treatment efficiency. The reserve amount should be estimated based on daily usage and the maximum possible demand for emergency response, generally not less than one month's usage. When storing, attention should be paid to moisture prevention and avoiding the medication from getting damp and clumping.

 

For nutrients such as nitrogen, phosphorus, potassium, etc., they should be stored according to the needs of microorganisms in wastewater. When sudden changes in water quality lead to microbial nutrient imbalance, timely supplementation of nutrients can help maintain microbial activity and metabolic function. The reserve amount should be determined based on the tank capacity and microbial population of the sewage treatment plant, usually ensuring a supply of about two weeks.

 

In addition, a certain amount of chemical oxidants such as potassium permanganate and hydrogen peroxide can be stored to cope with situations where the concentration of organic matter is too high; And chemical reducing agents, such as sodium sulfite, are used to treat certain oxidative pollutants that exceed the standard.

 

tube diffuser

 

When reserving emergency supplies, a strict inventory management system should be established. Regularly inspect materials to ensure their quality and performance are in good condition. For materials that are approaching their expiration date or have expired, they should be replaced and replenished in a timely manner.

 

3. Process adjustment of wastewater treatment

If the chemical oxygen demand (COD) and biochemical oxygen demand (BOD) of the incoming water suddenly increase

 

(1) Increase aeration rate: By increasing the operating power of the sewage aeration equipment or increasing the number of wastewater aeration devices turned on, more oxygen is provided to the treatment tank to meet the oxygen demand of microorganisms when decomposing high concentration organic matter. This helps to enhance the metabolic activity of microorganisms and accelerate the degradation of organic matter.

(2) Extending hydraulic retention time: This can be achieved by reducing the inflow rate or temporarily increasing the effective volume of the treatment tank. Longer residence time provides microorganisms with more opportunities to fully contact and react with organic matter, thereby improving the efficiency of organic matter removal.

(3) Supplementing microbial agents: If the concentration of organic matter exceeds the processing capacity of the original microorganisms, adding an appropriate amount of microbial agents with efficient degradation ability can quickly enhance the decomposition ability of the treatment system for organic matter.

(4) Adjust the sludge return ratio: increase the sludge return ratio appropriately to bring more activated sludge back to the biological treatment unit, increase the concentration of microorganisms, and enhance the removal efficiency of organic matter.

 

For situations where ammonia nitrogen suddenly increases

(1) Increase the dosage of nitrifying bacteria: Directly add cultured and domesticated nitrifying bacteria to the treatment system to rapidly increase the number and activity of the nitrifying bacterial community and improve the rate of nitrification reaction.

(2) Adjust reflux ratio: Increase the reflux rate of the nitration solution to send more nitrate nitrogen back to the anoxic zone for denitrification, thereby removing more ammonia nitrogen.

(3) Optimize aeration zoning: Based on the distribution of ammonia nitrogen, adjust the aeration zoning reasonably to ensure sufficient oxygen supply in areas with high ammonia nitrogen concentration, and promote nitrification reaction. Control dissolved oxygen concentration: Control the dissolved oxygen concentration in the aerobic zone within an appropriate range (generally 2-4mg/L), which not only meets the requirements of nitrification reaction, but also avoids excessive aeration from inhibiting nitrifying bacteria.

 

When the heavy metal content exceeds the standard

(1) Chemical precipitation method: Add an appropriate amount of chemical precipitant, such as sulfides (such as sodium sulfide), hydroxides (such as sodium hydroxide), etc., to form insoluble precipitates with heavy metal ions. By adjusting the dosage of precipitant and reaction conditions, heavy metals can be precipitated as much as possible.

(2) Ion exchange method: using ion exchange resin to adsorb heavy metal ions in water. In emergency situations, the number of ion exchange columns can be increased or the speed of water flow through the ion exchange columns can be increased to enhance the removal efficiency of heavy metals.

(3) Membrane separation technology: using membrane separation equipment such as reverse osmosis membranes or nanofiltration membranes to filter wastewater containing heavy metals, so that the heavy metals are intercepted and removed. During emergency response, the operating parameters of the membrane can be optimized to improve treatment efficiency.

 

If the pH value deviates from the normal range

When the pH value is too high, acidic substances such as sulfuric acid, hydrochloric acid, etc. should be added, and the changes in pH value should be closely monitored to avoid excessive adjustment leading to a low pH value. If the pH value is too low, add alkaline substances such as sodium hydroxide, lime water, etc. for neutralization. During the addition process, it should be added evenly and slowly to prevent sudden changes in local pH values from impacting the treatment system.

 