May 19, 2025

MBR Process in Wastewater Treatment

Leave a message

The flux of MBR membrane is determined by the membrane material and structure. For a specific membrane treatment unit, its porosity and flux have upper limits. Filtration is essentially a physical process. The membrane material must sacrifice the throughput while reducing the pore size, while also taking into account strength and ensuring long-term operation, which results in the flux being a fixed value.

 

The MBR process is essentially a combination of activated sludge method and membrane filtration. It replaces the secondary sedimentation tank with membrane filtration on the basis of the traditional activated sludge method, which brings advantages such as good interception and high sludge concentration, but this does not mean that the MBR process can solve all problems.

For the removal of pollutants, membrane filtration has a very obvious effect on SS, while the removal of organic matter still depends on the biodegradability of activated sludge and organic matter. For sewage with poor biodegradability or sewage that has been fully biochemically treated in the previous stage, MBR is also limited.

 

Due to the excellent interception effect of membrane filtration, the activated sludge in the MBR process can reach a higher concentration, realizing the separation of hydraulic retention time and sludge age, and the impact of sludge concentration on effluent can be ignored.

However, this advantage only increases the space for biochemical development. Not affecting effluent cannot be used as a reason to support not discharging sludge. The question of whether to discharge sludge or not still has to go back to activated sludge.

If sludge is not discharged, the activated sludge will age, which will affect the performance of biochemical and aeration. The MBR process in the project can indeed reduce sludge discharge, but it does not mean that it will not be discharged.

 

Membrane blockage is a common problem in MBR applications. It is the sludge that blocks the membrane, especially when the sludge concentration is too high. Therefore, there is a misunderstanding that reducing the sludge concentration can avoid membrane blockage, which is exactly another misunderstanding.

Sludge with too low or too high concentrations will quickly block the membrane. The correct approach is to keep the concentration within an appropriate range. In addition, aeration has the function of flushing the membrane surface, and it should also be kept at a corresponding retention amount.

 

The principle of the membrane itself is filtration, which is a physical process. The removal of pollutants is mainly SS. Its significance to MBR is that it improves the biochemical performance, but it cannot filter out soluble organic matter. Therefore, it cannot be responsible for indicators such as COD. The removal of organic matter still depends on the design and operation management of the entire process chain.

 

The MBR process is a combination of the activated sludge process and membrane filtration. It originated from the combination of the traditional activated sludge process and the secondary sedimentation tank. In this sense, the MBR process is applicable to scenarios where the activated sludge process is used.

 

Except for the good performance in disinfection performance and turbidity, other performances have nothing to do with the membrane. Moreover, the use of the membrane has strict requirements on the water volume change of the system. The flexibility of operation must have a large enough space, otherwise the membrane will be difficult to cope with the change of water volume.

The so-called MBR technology is the effective combination of microbial technology and membrane separation technology. In essence, it is microbial technology and membrane separation technology separately. It is difficult to reflect its effectiveness when operating independently. For example, the earliest MBR technology: the former MBR technology of aerobic + secondary sedimentation + ultrafiltration, its main function is to have good performance in disinfection performance and turbidity. The popular built-in or external MBR technology now, without a doubt, is the organic combination of microbial technology and membrane separation technology, achieving the effect of 1+1>2.

 

The pore size of the filter membrane used in most MBR technologies is basically between 0.05-0.4 microns, which is between ultrafiltration and microfiltration. The retention effect on microorganisms is obvious.

 

The pore size of the filter membrane used in most MBR technologies is basically between 0.05-0.4 microns, which is between ultrafiltration and microfiltration. The retention effect on microorganisms is obvious.

 

Due to the interception of SS by the membrane, the MBR process produces more sludge than the traditional activated sludge process. Low sludge production requires a sufficiently long sludge age, at which point the investment and operating costs will rise significantly.

The interception of SS by the membrane has no direct relationship with the sludge production. The microorganisms in the MBR system are in the endogenous respiration stage, and it is an obvious fact that the sludge production is low.

 

 